Diagnosis and troubleshooting methods for common faults of air compressors

2024-09-19 11:48:52 read()

The causes of unit failures are diverse, and a fault is usually not caused by a single component or factor, so the diagnosis and elimination of faults are often difficult.

The diagnosis and troubleshooting table is based on practical applications and extensive testing by manufacturers. This table indicates the common faults that may occur in the unit and the general causes of the above faults, as well as how to eliminate them, but it is not possible to list all faults and their elimination methods.


Before repairing or replacing components, a comprehensive and systematic analysis of various possible factors that may cause malfunctions should be conducted. When encountering problems, one should carefully observe, idenify faults, determine the cause, and then carry out necessary maintenance work to avoid causing unnecessary damage to the unit.


b. Check for damaged pipelines;


1. The power supply is not connected; Close the power switch to turn on the power.

2. The fuse in the control circuit is blown; Replace the fuse, identify the cause and solve it.

3. High exhaust temperature causing high temperature shutdown; Resolve according to the section on "Excessive exhaust temperature or excessive oil injection temperature", and then restart the compressor.

4. The thermal overload relay is disconnected; Correct the cause of overload and reset the thermal overload device.

5. Low voltage; Please have the power department check the input voltage and compare it with the motor terminal voltage. Check the reason for the low voltage.

6. Power failure; Check the power supply section.

7. Loose wiring; Check all wiring endpoints and tighten them.

8. Temperature sensor malfunction; Check the sensor and contact professional personnel for repair matters.

9. Transformer malfunction; Check the secondary voltage of the transformer.


Unexpected shutdown


Fault Symptoms and Possible Causes Troubleshooting Methods


1. The exhaust pressure is too high; Set the unloading pressure lower.

2. Low voltage; Check the input voltage and current under full load conditions.

3. Loose wiring of thermal overload relay; Tighten the wiring screws of the thermal overload relay.

4. Incorrect setting of thermal overload relay; Check the motor nameplate and compare it with the overload relay setting.

5. Loose wiring of motor or starter; Check if all wiring is tightened.

6. Motor malfunction; Send the motor to the manufacturer for testing, and check the wiring between the motor and starter before removing the motor.


Insufficient gas supply


Fault Symptoms and Possible Causes Troubleshooting Methods


1. There are too many leaks in the working pipeline; Check the leakage of the work pipeline with soapy water.

2. The intake valve is not fully open; Check the fault according to the section "Inlet valve not opened or closed according to air demand".

3. Air filter blockage; Clean or replace the air filter.

4. Incorrect setting of the regulating valve; Adjust the volume control valve again to obtain the desired adjustment range.

5. The pressure gauge of the gas storage tank is damaged; Check the cause and replace if damaged.

6. Excessive demand for air; Re evaluate the demand and add an additional machine if necessary.


The pressure of the gas storage tank is too high


Fault Symptoms and Possible Causes Troubleshooting Methods


1. Insufficient cooling water in the cooler; (Water cooled only) Clean the cooler. Check the water system for faults, including the water temperature regulating valve. If necessary, adjust or clean it again.

2. Insufficient air circulation in the cooler; Check the installation position of the cooler to ensure that there is no obstruction to the airflow. Check the cooler and clean it if necessary.

3. The oil level in the oil-gas separator is too low; Refuel to the recommended height and check for any leaks in the oil system.

4. Oil filter blockage; Replace the oil filter element.

5. Blockage of oil cooler; Check for paint film and rust deposits, and thoroughly clean the cooler according to the recommended method by the heat exchanger manufacturer.

6. The ambient temperature is too high; The ambient temperature should not exceed the higher ambient temperature at which the machine is operating.

7. Fan rotation direction is incorrect; The correct direction is for the fan to push air into the cooler and swap any two phases of the three-phase power cord.

8. Incorrect lubricating oil; Use Bao Le Te rotor lubricating oil. Refer to the lubrication section

9. Air filter blockage; Clean or replace the air filter

10. The temperature control valve is damaged; Repair or replace as needed

11. The compressor head is damaged; Contact the after-sales service department of Bao Le Te


Excessive consumption of lubricating oil


Fault Symptoms and Possible Causes Troubleshooting Methods


1. The air filter is damaged or unsuitable for the operating environment; Replace the damaged air filter core. If it is not suitable for the operating environment, a heavy-duty air filter can be used or the suction of the compressor can be guided to a place with clean air.

2. Oil filter malfunction; Replace the oil filter core and use genuine filters from Bao Le Te Company.

3. Damaged or inappropriate oil and gas separator core; Replace the separator core and use genuine filter cores from Bao Le Te Company

4. Lubricating oil deterioration; Refer to the "Maintenance - Lubricating Oil" section to solve the problem

5. Operate in extreme environments such as high temperature, high humidity, or high pressure; Run the compressor at the rated pressure and oil temperature of the oil-gas separator to accelerate the replacement cycle of lubricating oil or filters.

6. Lubricating oil is contaminated; Replace the lubricating oil and inspect and maintain the air filter core oil filter according to the daily maintenance schedule.

7. Mixing lubricating oils of different grades or models; Do not mix lubricants of different grades and models, and do not use lubricants from different manufacturers.

8. Using the wrong lubricating oil; Refer to the lubricating oil section of the operation manual.

9. Improper use of lubricating oil; Use lubricating oil as recommended. See lubrication section


Lubricating oil is discharged from the vent valve


Fault Symptoms and Possible Causes Troubleshooting Methods


1. Incorrect oil filter; Use genuine Bao Le Te spare parts.

2. Air filter malfunction; Replace the air filter and only use genuine Liuzhou Fuda air compressor accessories.

3. Lubricating oil deterioration; Search for faults in the "Maintenance - Lubricating Oil" section.

4. The system is contaminated; Check and remove dust, corrosive materials, paint film, and sludge from the system.


Frequent blockage of air filter


Fault Symptoms and Possible Causes Troubleshooting Methods


1. Control excessive moisture in the pipeline; Maintain and control the pipeline daily.

2. The intake valve is working incorrectly; Check the cylinder, valve sleeve and other components, and replace them if necessary.

3. The air intake valve is stuck; Check the intake valve, valve sleeve, or shaft, and replace if necessary.

4. Electromagnetic valve malfunction; Repair or replace as needed, and check the wiring before replacement.

5. The electromagnetic valve wire connector is loose; Check and tighten the wire terminals.


When the demand for compressed air decreases, the Saman air compressor cannot unload


Fault Symptoms and Possible Causes Troubleshooting Methods


1. Loose wire connections; Check all wire connections.

2. The intake valve is stuck; Check and repair.

3. Fault in the regulating valve; Clean the throttle hole of the volume control valve or replace the volume control valve.

4. Incorrect loading pressure setting; Reset the loading pressure.

5. The solenoid valve is damaged; Repair or replace.


Fault phenomenon and possible causes of fast transition between loading and unloading


Troubleshooting methods


1. Blockage of water/gas separator; Cleaning or replacement

2. Installation/application failure; Check other compressors in the same system

3. Leakage of water cooler; (Water cooled only) Replace the water cooler


Abnormal opening of safety valve


Fault Symptoms and Possible Causes Troubleshooting Methods


Preparation before maintenance and repair


1. Cut off the power supply of the host and hang a sign at the power switch.


3. Open the manual vent valve to vent the pressure in the system and keep the vent valve open.


5. Ensure that the compressor unit has cooled down to prevent burns and scalds.


-Don't assume that just because the machine is shut down, maintenance work can be carried out. The automatic control system of the machine will start the compressor at any time.


-Do not disassemble nuts, oil plugs, or other parts while the compressor is running or under pressure.


-Do not use flammable solvents such as gasoline or kerosene to clean air filters or other components. You should use and install according to the instructions.


Online Service